Korea Digital Co., Ltd. SENSECUBE
Product Introduction
O2 Sensor Probe
KCD-ON420
-
Range
0~25% (Zirconia type) -
Output
4~20mA or 0~5VDC, RS-485(Modbus RTU) -
Power
DC12~24V
Technical Data
Measurement | Measurement range | 0.1⁽¹⁾ ~ 25.0 %O₂ |
Sensing method | Solid electrolytes (Zirconia) | |
Accuracy After Calibration⁽²⁾ | ±0.5 % O₂ | |
Repeatability | < 30sec (90% Value) | |
General Conditions | Operating Temperatur | -10 ~ 50 ℃ |
Operating Humidity | 0~85%RH, (non condensing) | |
Sensor life | More than 3 years, (with power connection) |
|
Electrical | Power supply | 12~24 VDC⁽³⁾ |
Power consumption | About 3W | |
Electrical Spec Dimensions | Analog output (Option ) | 4~20mA, (or 0~5 VDC, 0~10VDC) |
Communication | RS-485 (Modbus RTU) | |
Dimensions | Sensor Φ25mm x 115mm Cable 5C (22AWG) x 1.5m |
|
Weight | Sensor 50g, Cable 70g |